Buy links on this page go through our /go/ redirects to the manufacturer or retailer. We earn nothing from them today; that may change. Disclosure.
Quick answer
RP46074 is Delta's single-function, pressure-balance cartridge for MultiChoice 13/14 series tub and shower valves made after March 2006.
Where to buy: genuine part from Delta.
Delta RP46074 on deltafaucet.comWhat it fits
- MultiChoice 13/14 series tub/shower trims on the MultiChoice universal valve, produced after March 2006 (Delta's product page). Delta's support article also lists floor-mounted tub fillers.
- Delta staff on the product page confirm it fits Celice 144705 trim.
- It does not fit 17 series trim. Delta staff point 17 series owners to RP46463.
RP46074 or RP19804?
Both are single-function Monitor cartridges, and they look similar. Delta's reference sheet and staff answers separate them like this:
| RP46074 | RP19804 | |
|---|---|---|
| Valves | MultiChoice 13/14, March 2006 and later | Monitor 1300/1400, before March 2006 |
| Upper housing color | Gray | White |
| Lower housing | Longer | Shorter |
| Legs | Delta says the post-2006 cartridge "has different shaped legs to fit the current valve roughs" | |
Delta's staff decline to call the two interchangeable. They recommend installing the part listed on your model's parts diagram.
Removal notes (from Delta's support article)
Shut off the water supply first.
- Remove the handle and slide off the metal sleeve.
- Unscrew the bonnet nut (hand-tight, or use a strap wrench). Make sure the valve body itself doesn't turn.
- Don't pry the cartridge out with a screwdriver. Put the handle back on, turn it about 1/4 turn counterclockwise past the stop, take it off, then grip the brass stem and pull straight out.
- Flush the valve with hot and cold, protecting the wall from spray.
- Install the new cartridge with "Hot Side" toward the hot supply (usually on the left).
The rattle test: Delta's article says that if you remove the cartridge in the full-on position and shake it, a rattle means the pressure-balance spool is working. No rattle means try tapping it, soaking it in 1:1 water and white vinegar for 30 minutes, or replacing it.
Delta lists the problems it solves: drips when off, leaks inside the handle, low flow on one temperature, or only one temperature no matter where the handle is.
Sources
Fetched and checked 2026-10-21. Part numbers change; confirm against your own valve and the maker before buying.